NIFPS

Leading Manufacturer of nitrogen injection fire protection system (nifps), nifps system for oil filled transformer and nitrogen injection fire protection system from Ghaziabad.

Nitrogen Injection Fire Protection System (NIFPS)

  • Nitrogen Injection Fire Protection System (NIFPS)
  • Nitrogen Injection Fire Protection System (NIFPS)
  • Nitrogen Injection Fire Protection System (NIFPS)
  • Nitrogen Injection Fire Protection System (NIFPS)
  • Nitrogen Injection Fire Protection System (NIFPS)
  • Nitrogen Injection Fire Protection System (NIFPS)
  • Nitrogen Injection Fire Protection System (NIFPS)
  • Nitrogen Injection Fire Protection System (NIFPS)
Nitrogen Injection Fire Protection System (NIFPS)
Get Best Quote
Rs 4,50,000  / SetPrice on Request

Minimum Order Quantity: 1 Set

Product Brochure

TypeTransformer Protection, Fire Suppression System
CapacityFor 2 MVA - 500 MVA Transformer
Usage/ApplicationTransformer Fire and Explosion Prevention
Fire Extinguisher TypeNitrogen Gas Based System
CertificationAs per CBIP & Type Tested
ColorP.O. Signal Red
Body MaterialCRCA Sheet
Automation GradeFully Automatic
Installation Services RequiredYes
Size/Dimension1750*1100*650 mm
DesignIn House
Weight300Kg
Pressure150 Bar(Nitrogen storage cylinder pressure)
FinishingPowder Coated
The traditional System like “High Velocity Water Spray System / Co2 Gas Flooding System” provides external protection of the transformers and they come into operation once the Fire got initiated around the transformer for the reason whatsoever or in case transformer already got exploded. Whereas “Nitrogen Injection Explosion prevention & Fire Protection System” is an internal protection of the transformer as it prevents the Transformer from its explosion which generally occurs due to over heating / overloading / winding Short-circuiting or for any earth fault etc., 
Please note that this system does not protect the transformer from its external Fire, since Nitrogen is injected inside the body of the transformer, Therefore “Nitrogen Injection Explosion prevention System” is not an alternative for HVWS / Co2 Flooding System but its Installation is recommended in addition to HVWS / Co2 Flooding System.

Additional Information:

  • Production Capacity: 1000 set annually
  • Delivery Time: 30 days
  • Packaging Details: As required

View Complete details

Yes! I am Interested Request a call back

NIFPS System for Oil Filled Transformer

  • NIFPS System for Oil Filled Transformer
  • NIFPS System for Oil Filled Transformer
  • NIFPS System for Oil Filled Transformer
  • NIFPS System for Oil Filled Transformer
  • NIFPS System for Oil Filled Transformer
  • NIFPS System for Oil Filled Transformer
  • NIFPS System for Oil Filled Transformer
NIFPS System for Oil Filled Transformer
Get Best Quote
Rs 4,55,000  / PiecePrice on Request

Product Brochure

TypeFire Suppression Systems
Capacity2-500 MVA
Usage/ApplicationOil filled Transformers
ColorPO Red
CertificationNABL Accredited Lab
Body MaterialMS Powder Coated
Automation GradeFully Automatic
Installation Services RequiredYes
Size/Dimension1750X1100X700 mm
DesignSelf/CBIP

View Complete details

Yes! I am Interested Request a call back

Nitrogen Injection Fire Protection System

Nitrogen Injection Fire Protection System
Get Best Quote
Rs 4,50,000  / SetPrice on Request

Minimum Order Quantity: 1 Set

Fire Fighting System TypeFire Suppression Systems
Capacity2 MVA To 500 MVA
Usage/ApplicationOil Filled Transformes
ColorPO Red
CertificationNABL IP 55 CBIP
Body MaterialMS CRCA Power Cotted
Installation Services RequiredYES
Automation GradeYES
Size/Dimension1100x1750x750
DesignOwn


Additional Information:

  • Production Capacity: 50 Per Month In General Shift
  • Delivery Time: 10-15 Days
  • Packaging Details: As Required.

View Complete details